Articulation trigger
Pull the articulation trigger to move the distal section from 0° toward 60°. The release button returns the section toward the straight position according to the IFU.
Bend the distal section from 0–60°, rotate the complete shaft through 360°, and operate the selected working end from the same hand. The platform is designed for laparoscopic steps where the camera, access axis, or a straight instrument restricts the preferred approach—across multi-port, reduced-port, and single-port access.
Product selection and use should follow the current IFU, labeling, hospital protocol, and target-market requirements.
The practical question is not how many articulation directions an instrument can claim. It is whether the surgeon can change the approach angle and continue the task without repeatedly changing grip or bringing in the other hand.
Pull the articulation trigger to move the distal section from 0° toward 60°. The release button returns the section toward the straight position according to the IFU.
Turn the rotation control to rotate the shaft around its longitudinal axis and redirect the plane of distal articulation.
Operate the rear handle to open and close the selected grasper, dissector, scissors or needle-holder working end.
A fully mechanical, reusable instrument. It is not a robotic wrist and does not claim 360° distal articulation.
A demonstration video will be added here after final review of the control sequence, captions and regulatory wording.
Recommended sequence: neutral position → distal articulation → axial shaft rotation → jaw operation → return to straight.
Articulation can be relevant whenever the camera, access axis or a straight instrument limits the preferred approach to the target. The need should be evaluated by task and geometry, not by port count alone.
Useful to evaluate when anatomy, camera position or trocar placement restricts the preferred straight-line approach.
Fewer or closer entry points can increase parallel shafting and external handle interference.
Distal articulation can provide another mechanical option when instruments enter through one access location.
Working lengths extend from 180 to 430 mm. Thoracoscopic applications remain a clinical-development and regulatory-assessment direction, not a current public indication claim.
The distal section bends from 0° to 60°. The shaft then rotates through 360° around its longitudinal axis. Together, the two manual functions allow the surgeon to redirect the working end without presenting the platform as a 360° distal wrist.
Define the exact step where the camera axis, anatomy, access angle or another instrument blocks the preferred trajectory.
Articulation only has value if the working end matches the tissue and task. Jaw geometry should be selected before evaluation.
Ask the surgeon to articulate, rotate, complete the task and return to straight while observing grip changes and use of the non-operating hand.
The immediate priority is surgeon evaluation of handling, working angle and working-end design. OEM, private-label and contract-manufacturing discussions remain available subject to technical and regulatory assessment.
The handle architecture places distal articulation, shaft rotation and jaw operation around the operating grip. This is the product's clearest evaluation question for surgeons.
The exact registered model list is preserved without adding unconfirmed energy functions.
P0006A-05-0 Curved Scissors and P0006A-06-0 Straight Scissors.
P0006A-08-0 Straight Needle Holder and P0006A-09-0 Curved Needle Holder.
Duckbill, Rat-Tooth, Ureter, Fallopian Tube, Long-Neck, Wolf-Tooth, and Upturned-Tip graspers.
P0006A-01-0 Curved Dissector and P0006A-07-0 Straight Dissector.
The model list is grouped for customer selection while preserving the exact model references.
| Group | Model | Configuration | Common Platform Information |
|---|---|---|---|
| Scissors | P0006A-05-0 | Curved Scissors | 5.0 mm · 0–60° articulation · 360° shaft rotation |
| Scissors | P0006A-06-0 | Straight Scissors | 5.0 mm · 0–60° articulation · 360° shaft rotation |
| Needle Holder | P0006A-08-0 | Straight Needle Holder | 5.0 mm · working length 180–430 mm |
| Needle Holder | P0006A-09-0 | Curved Needle Holder | 5.0 mm · working length 180–430 mm |
| Grasper | P0006A-02-0 | Duckbill Grasper | Reusable · supplied non-sterile |
| Grasper | P0006A-03-0 | Rat-Tooth Grasper | Reusable · supplied non-sterile |
| Grasper | P0006A-04-0 | Ureter Grasper | Reusable · supplied non-sterile |
| Grasper | P0006A-10-0 | Fallopian Tube Grasper | Reusable · supplied non-sterile |
| Grasper | P0006A-11-0 | Long-Neck Grasper | Reusable · supplied non-sterile |
| Grasper | P0006A-12-0 | Wolf-Tooth Grasper | Reusable · supplied non-sterile |
| Grasper | P0006A-13-0 | Upturned-Tip Grasper | Reusable · supplied non-sterile |
| Dissector | P0006A-01-0 | Curved Dissector | 5.0 mm · manual articulation |
| Dissector | P0006A-07-0 | Straight Dissector | 5.0 mm · manual articulation |
Start with the operative step, tissue interaction and access constraint. Then select the working end, length and cooperation pathway.
Select scissors, needle holder, grasper, or dissector and then the exact jaw geometry.
Choose within the registered 180–430 mm working-length range and consider the target anatomy, port placement, and intended conventional multi-port, reduced-port, single-port, or NOTES access context.
Record whether the surgeon reaches the target, maintains a stable grip, controls the selected jaw and returns the instrument to straight without unnecessary hand changes.
Public regulatory wording is stated by product, model, and target-market scope.
The product is supplied non-sterile and intended for validated reprocessing according to the current IFU. International evaluation, distribution and clinical use must follow the applicable requirements of each target market. CE review is ongoing; no current CE-marked claim is made. The current IFU describes laparoscopic use; thoracoscopic use is not presented as a current registered indication on this page.
Answers are aligned with the visible page content and current public documentation boundary.
The 0–60° specification refers to bending of the distal section. The 360° specification refers to axial rotation of the shaft around its longitudinal axis. They are separate functions.
The articulation trigger, shaft rotation control and jaw control are positioned within reach of the operating hand. The statement describes the control layout; it does not claim automated motion or simultaneous actuation of every function.
No. The public product information supports 0–60° distal articulation. The 360° function is shaft rotation, not a 360° wristed or robotic distal joint.
The current IFU describes use with laparoscopy. Longer-length and thoracoscopic applications are being treated as a clinical and market-development question and require the appropriate technical, clinical and regulatory assessment before they are presented as an indication.
The current family includes thirteen listed configurations across scissors, needle holders, graspers, and dissectors.
No. The platform may be evaluated in conventional multi-port, reduced-port, single-port, or NOTES access contexts where target anatomy, port placement, and working geometry make additional distal angles relevant. Final product selection and use must follow the current IFU, labeling, surgeon training, hospital protocol, and applicable market requirements.
The product is NMPA registered in China. CE review is ongoing; current CE marking has not been granted.
Yes. OEM, private-label, contract-manufacturing, and market-specific regulatory discussions are possible subject to technical assessment, quality agreement, and applicable regulatory requirements.
Tell us the procedure, difficult operative step, preferred working end, length requirement and target market. We can discuss a surgeon evaluation, distributor project or OEM pathway.