Single-Port Access System
Model-specific selectionSingle use · EO sterileCE by exact model scope

Choose the access route first.

AeroMed Single-Port systems combine a route-specific multi-channel sealing body, a matched incision retractor / protector and a ventilation tube. Selection starts with the access route, then incision requirement, channel layout and exact model.

Product selection and use should follow the current IFU, labeling, hospital protocol and destination-market requirements.

HK-FDDC-4FGD complete Single-Port Access System as a representative portfolio model
1 · Access routeTransumbilical, transvaginal, transanal or robotic.
2 · Incision requirementConfirm the intended incision and matched retractor / protector.
3 · Channel layoutConfirm instrument diameters and three-, four- or robotic-arm channel needs.
4 · Exact modelMatch the model, current IFU and destination-market documentation.
Product Architecture

Four access routes. Seven in-stock models.

Each configuration is presented by its real route and architecture. Hand-Assisted Access and Sealing Caps are separate Access System product groups and are not included as Single-Port models on this page.

HK-FDDC-4FGD and HK-FDDC-3FGD transumbilical single-port systems
Transumbilical

HK-FDDC-4FGD / 3FGD

D90 · 4 channels / D60 · 3 channels

Select by incision requirement, sealing-body diameter and instrument plan—not by an adult or pediatric label alone.

View configuration →
HK-FDDC-4FX transvaginal double-ring single-port system
Transvaginal

HK-FDDC-4FX / 4TNOS

D60 · 4 channels

Separate double-ring and balloon configurations for route-specific transvaginal access planning.

View configuration →
HK-FDDC-4NOS transanal single-port access system
Transanal

HK-FDDC-4NOS

D60 · 4 channels

Dedicated transanal architecture for model-specific evaluation and documentation.

View configuration →
HK-FDDC-5DF robotic single-port access system
Robotic

HK-FDDC-5DF / HK-TS-120.C

D90 robotic-arm channels / D120 four channels

Two in-stock robot-specific access architectures; confirm the target robot and instrument configuration before selection.

View configuration →
Selection Logic

A four-step selection process.

This keeps quotations and product discussions simple for distributors while preserving model-specific accuracy.

Step 1

Access route

Transumbilical, transvaginal, transanal or robotic.

Step 2

Incision requirement

Confirm the intended incision and matched retractor / protector.

Step 3

Channel layout

Confirm instrument diameters and three-, four- or robotic-arm channel needs.

Step 4

Exact model

Match the model, current IFU and destination-market documentation.

Model Matrix

In-stock Single-Port model summary.

The table focuses on current in-stock configurations and the information needed for model selection.

Access routeModelSealing bodyChannel layoutSelection position
TransumbilicalHK-FDDC-4FGDD904In stock · four-channel
TransumbilicalHK-FDDC-3FGDD603In stock · smaller-incision option
TransvaginalHK-FDDC-4FXD604Double-ring
TransvaginalHK-FDDC-4TNOSD604Balloon
TransanalHK-FDDC-4NOSD604Dedicated transanal
RoboticHK-FDDC-5DFD90Robotic arm / auxiliaryFor SHURUI and Jingfeng workflows
RoboticHK-TS-120.CD1204For selected da Vinci workflows
D60, D90 and D120 refer to nominal sealing-body diameter—not incision length. Confirm the matched incision retractor / protector and exact instrument configuration before quotation.
Factory & Distributor Clarity

One catalog, one clear product boundary.

This page covers Single-Port only. It does not merge Hand-Assisted Access or stand-alone Sealing Caps into the Single-Port family.

Controlled product information

Use the formal model, exact configuration and current controlled documents for every evaluation, quotation and registration project.

Complete system compositionSingle-Port models combine the multi-channel sealing body, matched incision retractor / protector and ventilation tube.
Instrument passage10-size valves accept 12 mm, 10 mm and 5 mm instruments; 5-size valves accept 5 mm and 3 mm instruments, subject to exact model configuration.
Regulatory wordingCE and other documentation must follow the current certificate, exact model scope, IFU and destination market.

Single-Port Access System Catalog

Download the current English PDF with route selection, product images and model summary.

Download Catalog (PDF)
Frequently Asked Questions

Single-Port Access System questions.

Concise answers for product evaluation, model selection and distributor communication.

What is included in an AeroMed Single-Port Access System?

A route-specific multi-channel sealing body, matched incision retractor / protector and ventilation tube are supplied as the complete access configuration.

Is HK-FDDC-3FGD only a pediatric model?

No. It is a D60 three-channel transumbilical configuration. Selection should be based on incision requirement, channel plan and matched retractor / protector; it may be evaluated for pediatric or other smaller-incision workflows.

Are Hand-Assisted Access and Sealing Caps part of this Single-Port page?

No. They belong to the broader Access System product scope but have separate product pages and catalogs.

Can distributors download the product catalog?

Yes. Use the Download Catalog button on this page to access the current Single-Port Access System PDF.

Confirm the exact Single-Port configuration.

Send the access route, required channels, intended instruments, target market and evaluation quantity.