Reusable support frame
A structural positioning frame used with a compatible SF working end.
Choose between an adjustable ball-joint configuration and a straight-rod configuration. HK-GDQ provides the reusable support structure; the compatible SF working end is selected separately.
Cleaning, inspection, sterilization, compatible working ends, and mounting hardware should follow the current IFU and technical documentation.
The page separates the reusable support structure from the disposable SF foot, avoiding the old wording that treated HK-GDQ as a complete standalone equivalent to the single-use Heart Stabilizer.
A structural positioning frame used with a compatible SF working end.
HK-GDQ itself does not perform the tissue-contact function.
It does not require the disposable suture holder as its mounting base.
No numerical reuse-cycle claim is published on this page.
The reusable frame provides support, adjustment, and positioning. A compatible SF working end is selected separately according to the documented configuration.

Ball-joint configuration for adjustable positioning of the support frame and compatible working-end interface.

Straight-rod configuration for a more standardized support geometry in documented cardiac stabilization workflows.
Both frame variants require a compatible disposable SF working end where documented. The frame itself is not the tissue-contact component.
The previous page incorrectly centered the disposable suture holder as the mounting base. The revised page reflects the separate HK-GDQ support pathway.
Select Q or Z according to the required positioning geometry and current technical file.
Review the compatible bedside or table-side support hardware during technical evaluation.
Match the frame to a permitted SF working end and applicable IFU.
The reusable frame requires hospital preparation before use according to the current IFU.
Follow validated reprocessing instructions and institutional procedures.
This page does not publish a numerical reuse-cycle claim. Retirement criteria should follow the approved documentation.
| Parameter | Public Website Information |
|---|---|
| Models | HK-GDQ-Q · HK-GDQ-Z |
| Device type | Reusable cardiac stabilizer support frame / arm |
| Connection geometries | Adjustable ball-joint · straight rod |
| Material | Surgical-grade stainless-steel construction according to source documentation |
| Supply condition | Non-sterile |
| Working end | Compatible disposable SF foot or positioning end where documented |
| Mounting | Compatible bedside or table-side support arrangement; confirm during evaluation |
| Reprocessing | Cleaning, inspection, disinfection, and sterilization per current IFU |
| Manufacturer | Beijing HangTian KaDi Technology R&D Institute |
HK-GDQ is presented as CE MDR Class I reusable. This status belongs to the reusable support frame and should not be merged with the CE Class III or FDA listing status of the single-use Heart Stabilizer.
HK-GDQ is a reusable cardiac stabilizer support frame. It provides structural support and positioning for a compatible disposable SF working end. The frame is not the tissue-contact foot.
HK-GDQ-Q uses an adjustable ball-joint connection, while HK-GDQ-Z uses a straight-rod structure. Selection should follow the required positioning geometry, compatible working end, mounting arrangement, and current documentation.
No. The HK-GDQ reusable frame is evaluated with a compatible bedside or table-side support arrangement and does not require the disposable suture holder as its mounting base. The exact hardware should be confirmed during technical evaluation.
The source page presents the SF working-end family as shared with HK-GDQ where supported by AeroMed configuration and distributor documentation. The exact permitted pairing must be confirmed against the current IFU and model matrix.
This website does not publish a numerical reuse-cycle claim. Cleaning, inspection, disinfection, sterilization, and service-life decisions should follow the current IFU, validated reprocessing documentation, and hospital procedure.
HK-GDQ is presented as CE MDR Class I reusable. Current certificate, declaration, IFU, model list, and reprocessing documents are available to qualified partners.
Specify Q or Z interest, target country, holding arrangement, preferred SF working end, reprocessing-document needs, and evaluation quantity.