Laparoscopic Sealing Cap
HK-TS-60 / 90 / 120 Requires Compatible Wound Retractor Single-Use Sterile

HK-TS Sealing Cap for protected laparoscopic access.

Used with a compatible AeroMed wound retractor or protector, the HK-TS cap helps maintain pneumoperitoneum and provides direct access for suitable laparoscopic instruments through one integrated self-sealing channel.

Product selection and use should follow the current IFU, labeling, hospital protocol, and target-market requirements.

AeroMed HK-TS laparoscopic sealing cap with integrated self-sealing instrument channel
3 standard sizes 60 · 90 · 120 mm
Direct instrument access No separate trocar required
Supports pneumoperitoneum When correctly assembled
Compatible retractor required Cap is not standalone
Quick Answer

What is the HK-TS Sealing Cap?

It converts a protected surgical incision into a sealed single-channel laparoscopic access configuration.

Product role

Maintains sealed access

The cap and compatible wound retractor work together to support pneumoperitoneum.

Required pairing

Incision established first

The wound retractor forms the protected pathway before the cap is attached.

Instrument access

Integrated self-sealing channel

Suitable instruments pass directly through the channel without a separate trocar.

Standard range

60 / 90 / 120 mm

Select the cap with its documented compatible wound-retractor model.

System Relationship

From protected incision to sealed laparoscopic access.

The clinical objective is comparable to a laparoscopic wound-retractor cap, but the HK-TS design integrates the self-sealing access channel.

Three-part access logic

1. Create the surgical incision and position the compatible wound retractor or protector.

2. Attach the HK-TS Sealing Cap to the external ring to close the access site.

3. Pass suitable laparoscopic instruments directly through the integrated self-sealing channel while the assembled system supports pneumoperitoneum.

Protected incision + compatible wound retractor + HK-TS cap = sealed single-channel laparoscopic access
HK-TS Sealing Cap assembled on a compatible AeroMed wound retractor at the protected incision
Assembled configuration

Cap attached after the wound retractor is positioned

The cap seats on the external ring after the wound retractor has established the protected sleeve through the incision.

Standard Size Range

Three standard single-channel configurations.

The model number indicates the nominal diameter group; exact pairing and dimensions should be confirmed.

AeroMed HK-TS-60 single-channel laparoscopic sealing cap
D60 · Single Channel

HK-TS-60

Standard small-diameter Sealing Cap configuration.

Use with the documented compatible wound retractor / protector.
AeroMed HK-TS-90 single-channel laparoscopic sealing cap
D90 · Single Channel

HK-TS-90

Standard medium-diameter Sealing Cap configuration.

Use with the documented compatible wound retractor / protector.
AeroMed HK-TS-120 single-channel laparoscopic sealing cap
D120 · Single Channel

HK-TS-120

Standard large-diameter Sealing Cap configuration.

Use with the documented compatible wound retractor / protector.
Model Matrix

Three standard HK-TS sealing-cap models.

All three models use one integrated self-sealing access channel. Confirm the matching wound retractor and instrument-size range before ordering.

Formal Model Nominal Diameter Channel Design Selection Logic
HK-TS-60 60 mm Integrated self-sealing single channel Use with the documented compatible smaller-size wound retractor / protector.
HK-TS-90 90 mm Integrated self-sealing single channel Use with the documented compatible medium-size wound retractor / protector.
HK-TS-120 120 mm Integrated self-sealing single channel Use with the documented compatible larger-size wound retractor / protector.
Customer Selection

Choose by cap diameter and compatible sleeve.

Choose the cap and wound-retractor combination first, then confirm instrument diameter and target-market documentation.

Diameter

Match the wound-retractor configuration

Start with the required access diameter and confirm the compatible wound retractor.

  • 60 / 90 / 120 mm group
  • Confirm matching retractor model and sleeve length
Access Function

Direct access without a separate trocar

Suitable laparoscopic instruments enter through the integrated self-sealing channel after the incision and wound retractor are in place.

  • Designed to support pneumoperitoneum
  • Confirm permitted instrument diameter in the current IFU
Workflow

Use after surgical incision

HK-TS is not a puncture-entry trocar. It is attached after the compatible wound retractor establishes the protected access pathway.

  • Supports access before or after specimen retrieval
  • Separate multi-channel and robotic platforms are available
Compatibility boundary: do not state that every HK-TS cap fits every HK-FQ wound retractor. The exact cap-and-sleeve pairing must be confirmed in the model matrix and IFU.
Regulatory Status

Regulatory documentation follows the exact cap and sleeve combination.

Public regulatory wording is stated by product, model, and target-market scope.

Public status

CE documentation is available for HK-TS-60, HK-TS-90 and HK-TS-120 according to the current certificate and model scope. Confirm the exact cap-and-retractor combination for the target market.

Model and pairing matrix Confirms cap diameter, channel configuration and compatible wound retractor.
IFU and labeling Confirms assembly, pneumoperitoneum workflow, warnings, and disposal.
Technical information Instrument-size range and operating instructions follow the current product specification and IFU.
Frequently Asked Questions

Sealing Cap questions.

Quick answers for distributors, clinicians and procurement teams evaluating the HK-TS system.

What is a laparoscopic sealing cap for a wound retractor?

It attaches to a compatible wound retractor after the incision is established, converting the protected incision into a sealed single-channel laparoscopic access configuration.

Does the HK-TS Sealing Cap require a separate trocar?

No separate trocar is required for the integrated self-sealing channel. Suitable laparoscopic instruments pass directly through the channel according to the current IFU and model specification.

Can the HK-TS configuration maintain pneumoperitoneum?

When correctly assembled with a compatible wound retractor, the HK-TS configuration is designed to support pneumoperitoneum during laparoscopic access.

Is the HK-TS Sealing Cap used to puncture the abdominal wall?

No. The incision is created first and the compatible wound retractor forms the protected access sleeve. The cap is then attached externally.

Which HK-TS models are available?

The standard lineup includes HK-TS-60, HK-TS-90 and HK-TS-120. Confirm the exact cap and wound-retractor pairing before ordering.

Product Resources

Download the HK-TS Sealing Cap Catalog.

Review the standard models, product relationship, sterilization method and shelf-life information in one concise document.

Evaluate the HK-TS cap-and-retractor combination.

Tell us the required access diameter, intended laparoscopic workflow, target country and evaluation quantity.