Home/Products/Specimen Retrieval Bag
General Surgery & Retrieval
Ordinary · 10 ReferencesHang T Safe · 30 References5 Nominal Sizes

One retrieval family. Two workflow paths.

Choose the Ordinary retrieval bag for routine specimen containment and extraction, or Hang T Safe when a configurable contained-access architecture is required. For Hang T Safe, plan the working paths first, then select A, C or E, the nominal bag-mouth size and the ligature-rope option.

AeroMed Hang T Safe Shape C specimen retrieval bag with two color-coded working sleevesView Hang T Safe A / C / E →
40total family references
10Ordinary references
30Hang T Safe references
40–130 mmnominal bag-mouth range
Quick Answer

Start with the retrieval workflow, not only the size.

Ordinary and Hang T Safe support different retrieval architectures. For Hang T Safe, A / C / E identifies one, two or three independent working paths; the size identifies the nominal bag-mouth opening and -S identifies the ligature-rope option.

Product Group

Ordinary or Hang T Safe

Start with the requested retrieval workflow and controlled IFU.

Access Architecture

No letter or A / C / E

No letter is Ordinary; A, C and E identify Hang T Safe with 1, 2 or 3 independent working sleeves / finger channels. More channels do not mean a higher product grade.

Size

40 / 60 / 80 / 100 / 130

Five nominal bag-mouth sizes are available.

Rope Option

No -S or -S

No -S means without a ligature rope; -S means with a ligature rope.

Product Groups

Choose the product group before the size.

Ordinary and Hang T Safe configurations use different model logic and should be selected separately.

Ordinary specimen retrieval bag without ligature rope
Ordinary · Without Rope

Base HK-QW model

Routine specimen retrieval configuration without the -S ligature-rope suffix.

5 sizes · 40 / 60 / 80 / 100 / 130 mm
Ordinary specimen retrieval bag with ligature rope
Ordinary · With Rope

-S model

Corresponding Ordinary model supplied with a ligature rope.

5 sizes · -S suffix
Hang T Safe closed-bag specimen retrieval system
Hang T Safe · Closed Bag

A / C / E configurations

One, two or three independent working sleeves / finger channels, each available across five sizes and two rope states.

30 references · View dedicated page →
Hang T Safe Access Guide

A, C and E define different contained-access architectures.

Use the planned instrument pathways to identify the required Hang T Safe configuration: A provides one independent working sleeve / finger channel, C provides two and E provides three. More channels are not automatically better; select the architecture that matches the planned technique.

Hang T Safe specification A specimen retrieval bag with one working sleeve
Specification A

1 independent working path

Streamlined contained-access configuration with one finger channel.

Hang T Safe specification C specimen retrieval bag with two working sleeves
Specification C

2 independent working paths

Supports separate access paths for visualization and instrument use according to the planned technique and current IFU.

Hang T Safe specification E specimen retrieval bag with three working sleeves
Specification E

3 independent working paths

Expanded contained-access configuration when the planned technique requires additional independent instrument pathways.

Selection principle: Bag size and channel count should not be considered in isolation. Match the retrieval architecture to the planned workflow, instrument paths and current IFU. Image note: A and C are representative product views. The E view follows the controlled three-channel Shape E diagram; confirm final color and label details against the current approved product specification before ordering.
Model & Size Logic

The same five sizes support a clear order code.

Ordinary: HK-QW-[size] or HK-QW-[size]-S
Hang T Safe: HK-QW-[size] [-S when rope is supplied] ([A / C / E])
Nominal Bag-Mouth SizeBag DepthPuncture DeviceOrdinary OptionsHang T Safe Options
40 mm130 mm10 mmWithout rope / -S with ropeA / C / E · each without or with -S
60 mm180 mm10 mmWithout rope / -S with ropeA / C / E · each without or with -S
80 mm200 mm10 mmWithout rope / -S with ropeA / C / E · each without or with -S
100 mm220 mm10 mmWithout rope / -S with ropeA / C / E · each without or with -S
130 mm230 mm12 mmWithout rope / -S with ropeA / C / E · each without or with -S
Dimensional tolerance: bag-mouth opening ±10 mm; bag depth ±50 mm. Product selection and use must follow the current IFU, labeling, hospital protocol and surgeon judgment.
Supply & Regulatory Boundary

Simple public information; controlled details by model.

The family uses polyurethane / TPU bag film and is supplied EO sterile for single use with a three-year shelf life according to current labeling. Specimen Retrieval Bag FDA 510(k) K172789 documentation is available where applicable. CE and other market claims must be confirmed against the exact model and current controlled scope.

Frequently Asked Questions

Distributor ordering questions.

What is the difference between Ordinary and Hang T Safe?

Ordinary models use the base size code. Hang T Safe adds A, C or E to identify one, two or three independent working sleeves / finger channels for different contained-access architectures.

What does -S mean?

-S identifies the corresponding model supplied with a ligature rope. It does not mean “Safe.”

How many references are in the complete family?

There are 40 references: 10 Ordinary models and 30 Hang T Safe models.

What are A, C and E?

A has one independent working sleeve / finger channel, C has two and E has three. They describe access architecture, not product grade or a fixed procedure.

Does a higher channel count mean a better configuration?

No. Select the configuration according to the planned instrument pathways, current IFU, surgeon judgment and hospital protocol.

Which introducer size is required?

The 40–100 mm models use a 10 mm puncture device; the 130 mm model uses a 12 mm puncture device.

How should regulatory status be checked?

Confirm the exact model and target market against the latest controlled certificate, model schedule, IFU and labeling before registration, quotation or public claims.

Tell us what you need.

Ordinary or Hang T Safe · size · A/C/E when applicable · with or without ligature rope · target market.