Ordinary or Hang T Safe
Start with the requested retrieval workflow and controlled IFU.
Choose the Ordinary retrieval bag for routine specimen containment and extraction, or Hang T Safe when a configurable contained-access architecture is required. For Hang T Safe, plan the working paths first, then select A, C or E, the nominal bag-mouth size and the ligature-rope option.
View Hang T Safe A / C / E →Ordinary and Hang T Safe support different retrieval architectures. For Hang T Safe, A / C / E identifies one, two or three independent working paths; the size identifies the nominal bag-mouth opening and -S identifies the ligature-rope option.
Start with the requested retrieval workflow and controlled IFU.
No letter is Ordinary; A, C and E identify Hang T Safe with 1, 2 or 3 independent working sleeves / finger channels. More channels do not mean a higher product grade.
Five nominal bag-mouth sizes are available.
No -S means without a ligature rope; -S means with a ligature rope.
Ordinary and Hang T Safe configurations use different model logic and should be selected separately.

Routine specimen retrieval configuration without the -S ligature-rope suffix.

Corresponding Ordinary model supplied with a ligature rope.

One, two or three independent working sleeves / finger channels, each available across five sizes and two rope states.
Use the planned instrument pathways to identify the required Hang T Safe configuration: A provides one independent working sleeve / finger channel, C provides two and E provides three. More channels are not automatically better; select the architecture that matches the planned technique.

Streamlined contained-access configuration with one finger channel.

Supports separate access paths for visualization and instrument use according to the planned technique and current IFU.

Expanded contained-access configuration when the planned technique requires additional independent instrument pathways.
Ordinary: HK-QW-[size] or HK-QW-[size]-SHang T Safe: HK-QW-[size] [-S when rope is supplied] ([A / C / E])| Nominal Bag-Mouth Size | Bag Depth | Puncture Device | Ordinary Options | Hang T Safe Options |
|---|---|---|---|---|
| 40 mm | 130 mm | 10 mm | Without rope / -S with rope | A / C / E · each without or with -S |
| 60 mm | 180 mm | 10 mm | Without rope / -S with rope | A / C / E · each without or with -S |
| 80 mm | 200 mm | 10 mm | Without rope / -S with rope | A / C / E · each without or with -S |
| 100 mm | 220 mm | 10 mm | Without rope / -S with rope | A / C / E · each without or with -S |
| 130 mm | 230 mm | 12 mm | Without rope / -S with rope | A / C / E · each without or with -S |
The family uses polyurethane / TPU bag film and is supplied EO sterile for single use with a three-year shelf life according to current labeling. Specimen Retrieval Bag FDA 510(k) K172789 documentation is available where applicable. CE and other market claims must be confirmed against the exact model and current controlled scope.
Ordinary models use the base size code. Hang T Safe adds A, C or E to identify one, two or three independent working sleeves / finger channels for different contained-access architectures.
-S identifies the corresponding model supplied with a ligature rope. It does not mean “Safe.”
There are 40 references: 10 Ordinary models and 30 Hang T Safe models.
A has one independent working sleeve / finger channel, C has two and E has three. They describe access architecture, not product grade or a fixed procedure.
No. Select the configuration according to the planned instrument pathways, current IFU, surgeon judgment and hospital protocol.
The 40–100 mm models use a 10 mm puncture device; the 130 mm model uses a 12 mm puncture device.
Confirm the exact model and target market against the latest controlled certificate, model schedule, IFU and labeling before registration, quotation or public claims.
Ordinary or Hang T Safe · size · A/C/E when applicable · with or without ligature rope · target market.