Plan the working paths
Consider visualization, working-instrument access and whether an additional independent path is actually required.
Hang T Safe is a single-use contained retrieval family with A, C and E configurations providing one, two or three independent working paths. Choose the access architecture for the planned laparoscopic workflow first, then confirm the bag-mouth size and rope option.

For distributors and procurement teams, the first question is how many independent working paths the planned technique requires. Then confirm the nominal bag opening, rope option and exact model code.
Consider visualization, working-instrument access and whether an additional independent path is actually required.
A, C and E provide one, two or three independent working sleeves / finger channels. More channels do not mean a higher product grade.
Select one of five nominal bag-mouth sizes, then confirm whether a ligature rope is required.
EO sterilized with a three-year shelf life according to current labeling.
The letters identify the number of independent working sleeves / finger channels integrated into the contained bag. They do not define a procedure name, trocar count or product grade. Select the configuration that matches the planned technique.

Streamlined access configuration with one finger channel for a planned contained workflow.

Supports separate access paths for visualization and instrument use according to the planned technique and current IFU.

Expanded access configuration when the planned technique requires additional independent instrument pathways.
Before choosing A, C or E, map how the contained workspace is expected to be used. The exact sequence and compatible instruments remain IFU-led and procedure-dependent.
Confirm whether the planned technique requires a dedicated visualization path inside the contained workspace.
Confirm the planned route for the morcellator or other working instrument according to the exact configuration and IFU.
Only select additional channels when the planned technique genuinely requires another independent instrument pathway.
Consider specimen geometry, deployment, intracorporeal positioning and usable working space together with nominal bag dimensions.
After the required access configuration is clear, confirm the nominal bag-mouth size and rope state. Hang T Safe contains 30 orderable references: three access configurations × five sizes × two rope states.
HK-QW-[40 / 60 / 80 / 100 / 130] [-S when rope is supplied] ([A / C / E])| Nominal Bag-Mouth Size | Bag Depth | Puncture Device | Available Configurations | Rope Option |
|---|---|---|---|---|
| 40 mm | 130 mm | 10 mm | A / C / E | Without rope or -S with rope |
| 60 mm | 180 mm | 10 mm | A / C / E | Without rope or -S with rope |
| 80 mm | 200 mm | 10 mm | A / C / E | Without rope or -S with rope |
| 100 mm | 220 mm | 10 mm | A / C / E | Without rope or -S with rope |
| 130 mm | 230 mm | 12 mm | A / C / E | Without rope or -S with rope |
Transparent flexible film supports visualization and handling according to the IFU.
Opening component may use 1Cr17Ni7 stainless steel or nitinol according to the controlled model specification.
Puncture-device size is 10 mm for 40–100 models and 12 mm for the 130 model.
Supplied EO sterile for single use according to current labeling.
Three years from the sterilization date under the stated storage conditions.
Catalog and regulatory overview are available; controlled IFU, label and UDI files are provided at the appropriate project stage.
Specimen Retrieval Bag FDA 510(k) K172789 documentation is available where applicable. CE and other market statements must follow the current certificate and exact model schedule. Do not extend one model’s status to the full A / C / E family without controlled confirmation.
A means one independent working sleeve / finger channel, C means two and E means three. The letters describe access architecture, not product grade or a fixed procedure.
No. Select the number of working paths according to the planned technique, instrument pathways, current IFU, surgeon judgment and hospital protocol.
The -S suffix identifies a model supplied with a ligature rope. A model without -S is supplied without the rope.
There are 30 references: three sleeve specifications × five nominal bag-mouth sizes × two rope states.
Use the 10 mm puncture device for 40, 60, 80 and 100 mm models. The 130 mm model uses a 12 mm puncture device.
No. Hang T Safe is a single-use product supplied EO sterile according to current labeling.
Confirm the exact model and target-market scope against the current certificate, model schedule and controlled document package before registration, quotation or public claims.
A / C / E · 40 / 60 / 80 / 100 / 130 mm · with or without ligature rope · target market.